Turn on the main gas supply and take a
reading. If the manometer now reads 11 inches,
the thermostat is defective and must be
replaced.
(45)
If the by-pass screw test shows no change in
gas pressure, the problem lies with the gas
supply to the refrigerator. Shut off the gas
supply, remove the by-pass screw, replace it
with one that has an O-ring and turn on gas
supply. Remember to check for a gas leak. At
this time we will take a look at the rest of the
gas system.
(46)
The safety valve, or flame
consists of a brass alloy
failure
safety
device,
valve housing and
cap, an electro-magnet, and a thermocouple,
which generates 14 to 30 millivolts when heat is
applied to the tip. It is used to energize the
electro-magnet in the safety valve. The purpose
of this device is to insure that the flow of gas is
shut off in the event flame is lost at the burner.
If this should occur, the thermocouple cools,
the magnet loses it magnetic field and the
valve closes. Most failures of this device are
related to the magnet, not the thermocouple.
Should this happen, the complete safety valve
should be replaced.