Sun Microsystems, Inc.901 San Antonio RoadPalo Alto, CA 94303U.S.A. 650-960-1300Send comments about this document to: [email protected] StorEdge™
xAufstellung von Sun-GerätenAchtung – Um den zuverlässigen BetriebIhres Sun-Geräts zu gewährleisten und es vorÜberhitzung zu schützen, dürfen dieÖffnu
xiGehäuseabdeckungSie müssen die obere Abdeckung Ihres Sun-Systemsentfernen, um interne Komponenten wie Karten,SpeicherchipsoderMassenspeicherhinzuzuf
xiiModification du matérielNe pas apporter de modification mécanique ou électriqueau matériel. Sun Microsystems n’est pas responsable de laconformité
xiiiBloc-batterieAttention – Les unités Product Namecontiennent une batterie étanche au plomb(produits énergétiques portatifs n˚TLC02V50).Il existe un
xivPrecaución – Aplica la alimentación de CA alsistema.Según el tipo de interruptor de encendido que su equipotenga, es posible que se utilice uno de
xvBatería de litioPrecaución – En las placas de CPU Sun hayuna batería de litio insertada en el reloj detiempo real, tipo SGS Núm. MK48T59Y,MK48TXXB-X
xviNordic Lithium Battery CautionsNorgeCaution – Litiumbatteri —Eksplosjonsfare.Ved utskifting benyttes kunbatteri som anbefalt av apparatfabrikanten.
xviiContentsRegulatory Compliance Statements iiiPreface xix1. Product Description 1-1Product Appearance 1-2Product Description 1-5Standard Hardware Co
xviii Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001Bus Configuration Cabling 3-4Recommended External SCSI Cab
xixPrefaceThe Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual providesinformation and procedures about installing, operating,
PleaseRecycleCopyright2001SunMicrosystems,Inc.,901SanAntonioRoad,PaloAlto,CA94303-4900U.S.A.Allrightsreserved.Thisproductordocumentisdistributedunderl
xx Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001Typographic ConventionsShell PromptsTypeface Meaning Examples
Preface xxiRelated DocumentationAccessing Sun Documentation OnlineThe Products and Solution web site enables you to access Sun™ technicaldocumentation
xxii Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001Ordering Sun DocumentationFatbrain.com, an Internet profess
1-1CHAPTER1Product DescriptionThis chapter consists of the following sections: Section 1.1 “Product Appearance” on page 1-2 Section 1.2 “Product Des
1-2 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 20011.1 Product AppearanceFIGURE 1-1 Sun StorEdge D240 Server To
Chapter 1 Product Description 1-3FIGURE 1-2 Sun StorEdge D240 Rackmount Media Tray With Removable Front BezelFIGURE 1-3 Server Top Media Tray, Front V
1-4 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001FIGURE 1-4 Media Tray, Rear ViewFIGURE 1-5 Mounting RailPowe
Chapter 1 Product Description 1-5FIGURE 1-6 DVD-ROM and Tape Drives Partially Removed on Sleds1.2 Product DescriptionThe Sun StorEdge D240 Media Tray
1-6 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001Caution – To remove all power from a media tray, you must di
Chapter 1 Product Description 1-71.5 Software Requirements The Solaris 8 operating environment is required on the system. For diagnostic purposes, S
iiiRegulatoryComplianceStatementsYour Sun product is marked to indicate its compliance class:• Federal Communications Commission (FCC) — USA• Industry
1-8 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001
2-1CHAPTER2InstallationThis chapter consists of the following sections: Section 2.1 “Tools and Parts Needed” on page 2-1 Section 2.2 “Placement in t
2-2 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001FIGURE 2-1 Mounting Rail
Chapter 2 Installation 2-3FIGURE 2-2 Sun StorEdge D240 Rackmount Media TrayFIGURE 2-3 Flathead (A) and Panhead (B) Screws (Enlarged Profiles)/\AB
2-4 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001FIGURE 2-4 Mounting Ear
Chapter 2 Installation 2-52.2 Placement in the RackA maximum of four media trays can be installed in one rack cabinet.FIGURE 2-5 Media Tray Placement
2-6 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001FIGURE 2-6 Media Tray in Cabinet Shelf Location2.3 Installin
Chapter 2 Installation 2-72. Align the holes on a mounting ear with a corresponding pair of 12.7-mm (0.5-in. or1/2-in.) rack holes.The rack holes are
2-8 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001FIGURE 2-8 Attaching the Mounting Ear to the Media Tray4. Us
Chapter 2 Installation 2-9Note – If you are installing the mounting rails in the Sun StorEdge expansioncabinet, the key hole located past the recessed
iv Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001ICES-003ClassANotice-AvisNMB-003,ClasseAThis Class A digital
2-10 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 20019. Partially install the rear media tray screws. Do not tig
Chapter 2 Installation 2-11Caution – The server top media tray is heavy. Placing it on top of a deskside serverrequires two people.● Two installers li
2-12 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001
3-1CHAPTER3OperationThis chapter consists of the following sections: Section 3.1 “Drive Configuration” on page 3-2 Section 3.2 “Bus Configuration” o
3-2 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 20013.1 Drive ConfigurationFIGURE 3-1 Drive Location (Front View
Chapter 3 Operation 3-3Note – Before you substitute a different type of device (DVD to DDS4, for example)in the left or right drive location, be sure
3-4 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001Caution – Before you change the switch selection, be sure to
Chapter 3 Operation 3-5FIGURE 3-4 Full Bus Configuration Cabling3.2.2.3 Split Bus Cabling and Switch SettingNote – External termination is not require
3-6 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 20013.3 SCSI Host Connection RequirementThe media tray must be c
Chapter 3 Operation 3-73.4.1 Booting from the DVD-ROM Drive1. In the case of a dual DVD-ROM on a single bus configuration, one of the twodrives has a
vBSMIClassANoticeThe following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliancelabel.
3-8 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 20015. Append /sd@#,0:f to the device path, replacing # with the
Chapter 3 Operation 3-9FIGURE 3-7 Front LEDs (Front Bezel Removed)TABLE 3-4 Hard Drive Status LED Descriptions (Front of System)Indication StatusGreen
3-10 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001FIGURE 3-8 Power Supply Status LED LocationsTABLE 3-6 Power
Chapter 3 Operation 3-113.6 Troubleshooting3.6.1 Software Precautions Be sure that no two SCSI devices have the same target ID. With a split bus con
3-12 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 20013.6.2 Hardware ProblemsTABLE 3-7 lists problems that can oc
Chapter 3 Operation 3-132. AC indictor onDC indicator offFault Indicator onNo output from the power supply. Replace thepower supply.3. AC indicator of
3-14 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001
4-1CHAPTER4ServiceThis chapter consists of the following sections: Section 4.1 “Field Replaceable Units” on page 4-1 Section 4.2 “Hard Drives” on pa
4-2 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001Caution – You must halt all SCSI bus activity by unconfiguri
Chapter 4 Service 4-3While there is no Solaris system software that provides hot-plug functionality toshield the operating system from the physical re
vi Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001
4-4 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001f. Replace the front bezel on the media tray.4. Configure th
Chapter 4 Service 4-5Use the following procedure to configure a slice (single physical partition) on a diskto be used with a UFS. For instructions abo
4-6 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001You can use any hard drive you add to a Sun StorEdge media t
Chapter 4 Service 4-7For example, if the media tray is connected to a host adapter corresponding tocontroller c2 and you add a drive to the right slot
4-8 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 20015. Determine the file system(s) on the disk:For example, if
Chapter 4 Service 4-9c. Unlatch the drive bracket handle (on the right) to release it.d. Pull the bracket handle out and swing it open until it pushes
4-10 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001 If the replacement drive is of a different type than the
Chapter 4 Service 4-11Note – Save all the drive partitioning information immediately after configuringmetadevices or file systems for use when recover
4-12 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001f. Delete hot spares.If any drives are used by hot spare po
Chapter 4 Service 4-13d. Pull the bracket handle out and swing it open until it pushes against thechassis.e. Continue pushing the handle against the c
viiSafety Agency ComplianceStatementsRead this section before beginning any procedure. Thefollowing text provides safety precautions to follow whenins
4-14 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001c. Reattach any submirrors.For example:d. Re-create hotspar
Chapter 4 Service 4-154.3 DVD-ROM Drive, Tape Drive, or HardDrive on a Sled Assembly4.3.1 Removing a Sled AssemblyNote – Remove the front bezel from t
4-16 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 20014.3.2 Replacing a Sled AssemblyFIGURE 4-3 Securing the Sled
Chapter 4 Service 4-17FIGURE 4-4 Removing a Power Supply1. Disconnect the power cord from the faulty power supply assembly.2. Loosen the two captive s
4-18 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001FIGURE 4-5 Installing a Power Supply1. Holding the handle,
A-1APPENDIXAProduct SpecificationsThis appendix consists of the following sections: Section A.1 “Electrical Specifications” on page A-2 Section A.2
A-2 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001A.1 Electrical SpecificationsTABLE A-1 Sun StorEdge D240 Rac
Appendix A Product Specifications A-3A.2 Physical SpecificationsTABLE A-3 Physical SpecificationsRackmount Media Tray Server Top Media TrayHeight 85 m
A-4 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001A.3 Environmental SpecificationsTABLE A-4 Environmental Spec
Appendix A Product Specifications A-5A.4 Software SpecificationsTABLE A-5 Software SpecificationsSoftwareRelease LevelSolaris operating environment So
viiiSELV ComplianceSafety status of I/O connections comply to SELVrequirements.Power Cord ConnectionCaution – Sun products are designed to workwith si
A-6 Sun StorEdge D240 Media Tray Installation, Operation, and Service Manual • August 2001
ixLaser Compliance NoticeSunproductsthat use laser technologycomply with Class1laser requirements.CD-ROMCaution – Use of controls, adjustments, or the
Comments to this Manuals